• Fritsch GmbH Mahlen und Messen | Probenaufbereitung und Partikelmessung

    • Продукты
    • Решения
    • Сервис
    • Новости
    • О нас
    • Контакт
    • Главная
    • Контакты
    • Печать
    • erp
    • English USA
    • English UK
    • Deutsch
    • French
    • Russian
    • IT
    • ES
    • Chinese
    • Japanese
    • Домашняя страница
    • ·
    • Решения
    • ·
    • Области применения
    • ·
    • Окружающей среды
    • ·
    • Reports from this industry
    • ·
    • Sample preparation for refuse derived fuels
      • Области применения
        • Строительная промышленность
        • Биология
        • Химия
        • Механохимия
        • Сельского и лесного хозяйства
        • Геология / минералогия
        • Керамическая / стекольная промышленность
        • Искусственные материалы / текстильные изделия
        • Продуктов питания
        • Металлургия
        • Окружающей среды
          • Reports from this industry
          • Grinding reports from this industry
        • Лекарственные препараты
      • Поиск продукции
      • Протоколы измельчения

      Contact Applications Laboratory

      FRITSCH Applications Laboratory Ulrich Gerber
      Ulrich Gerber

      Phone: 0049 67 84 70 122

      gerber(at)fritsch.de

    • Мельницы FRITSCH в сфере экологии

      Ваша задача – наше решение: Узнайте больше о подготовке идеальных проб в сфере экологии. Ознакомьтесь с нашими отчетами о применении с советами по измельчению или воспользуйтесь нашей практичной базой данных протоколов измельчений с множеством примеров измельчения и их подробным описанием. - Отчеты и протоколы измельчений также представлены на английском языке -

       

      • Reports from this industry
      • Grinding reports from this industry

      Sample preparation of refuse derived fuels

      Refuse derived fuels: Plastic, wood and shredded waste: Here are some examples of more or less well sorted fractions. Here the spectrum spans blends like can be seen here: pure plastic waste or even wood.

      Common for all of them: they are energetic interesting additions during thermal processes. The most important parameter is therefore the heating value for example determined according to DIN 51900 “testing of solid and liquid fuels” and “determination of the heating values”.

      Very disturbing for the incineration plant  is the chlorine content, for example determined according to DIN 51727 „testing of solid fuels” and “determination of the chlorine content”

      Depending on the source and composition of the secondary fuels, additional parameters are to be analyzed, like for example loss due to burning according to DIN 38414-S3, BTEX according DIN 38407-F9, PAK according DIN 13877, PCB according DIN 38414-S20 or also even heavy metals.

      Prerequisite for the analysis is the supply of a representative sample. The sample must be processed so fine, that for the analysis to be weighed in amount corresponds with that of the entire material to be screened. But these samples are depending on their source mostly very heterogeneous. Therefore must mostly larger amounts between 1 and 10 litres be comminuted. As a sufficient fineness for the analysis is a sieving of 0.5 to 1 mm requested.

      Based on the amount of the material and its properties, only a cutting mill can be considered for this task. Furthermore, when considering that in order to avoid cross contamination, the cleaning of the instrument often lasts longer than the actual comminution, consequently only the Universal Cutting Mill PULVERISETTE 19 can be recommended. The mill distinguishes itself through:

      • Quick lock
      • Cutting rotor removable without tools
      • Sieve cassette removable without tools
      • No dead spaces which evade the cleaning

      If a sieving of 0.5 mm is desired, then most materials can only be prepared with a combination of the cutting mill with the cyclone separator. The cyclone separator generates an air current. It downright draws the materials from the funnel, and acts as a coolant during the comminution and fosters the movement of the material and therefore the passing through the sieve. The finished prepared sample is removed through the cyclone separator into a sample glass.

      Tests showed that a pre-comminution for example with a 4 mm sieve and an ensuing fine comminution with a 5 mm sieve, can in no case replace the cyclone separator. Rather the opposite is to be noticed. Are the above pictured foils additionally pre-comminuted, the final fineness of 0.5 mm is no longer obtainable. On the sieve accumulates a filz which stops the material throughput. Coarse material whirls in the grinding chamber and therefore keeps the sieve clear. The same is to be observed with material blends: the more heterogeneous the materials within a sample are, the better they can be prepared. Therefore should material blends not be sorted prior to the comminution. Separated though should be iron parts. Are samples with a non-ferrous heavy metal share prepared, or is the focus on heavy-metal-free preparation, cutting knives of other materials are available.

      Here a few examples: industrial waste, residual waste, and wood were prepared with the Universal Cutting Mill PULVERISETTE 19:

       

       

       

       

      After the preparation only a little material may remain in the grinding chamber of the Cutting Mill. On no account may it look like this.

       

       

       

       

      During this attempt material was processed without a cyclone separator through a 0.5 mm sieve. Of course not all material was put through. The user can mostly observe this (photo on the left) after opening the grinding chamber. The remaining residue can be disregarded, if the amount of throughput is large enough.

       

       

       

      Here the not comminuted remainder was collected and is situated next to the sample which passed through the sieve.

       

       

      Are the percentages of the in the grinding chamber remaining amounts too large in comparison to the entire sample, or is it assumed, that remainders have a different composition than the comminuted sample, then the following recommendations apply:

      • pre-comminute with the Universal-Cutting Mill PULVERISETTE 19 + sieve cassette 2 mm
      • divide the sample with the Rotary-Cone Sample Divider LABORETTE 27
      • finely comminute the representative sample amount from the first step with the Variable Speed Rotor Mill PULVERISETTE 14 and a 0.5 mm sieve or
      • mix the sample with dry ice and put it through the Universal-Cutting Mill PULVERISETTE 19 with a sieve cassette 0.5 mm and cyclone separator in one step
      • re-comminute with dry ice without an additional sample

      Downloads / Grinding reports / Links

      Download the FRITSCH-report as PDF-file

      Sample preparation of refuse derived fuels

       

      Detailed grinding reports

      Paper

      back

    • Прямые ссылки
    • Вход
    • Контакты
    • ОУЗТС
    • Выходные данные
    • Рекомендовать страницу
    • Печать
    • Подготовка проб
    • Измерение частиц
      • Контакты / Сервис / Новости

         

        Контакты

        Консультация по использованию

        Техническая поддержка

        Контакты по всему миру

         

        Сервис

        Консультация по использованию

        Техническая поддержка

        Ваша задача - наше решение

        Поиск продукции

        Протоколы измельчения

        Бесплатной подготовке пробы

        Контакты по всему миру

        Загрузка

        Онлайн-гарантия

        Сертификаты качества

         

        Новости

        Новости

        Дорожные шоу

        Практикумы

        Выставки

      • Продукция для подготовки проб

         

        Измельчение

        Планетарные мельницы

        Шаровые мельницы

        Режущие мельницы

        Роторные и ударные мельницы

        Щековые дробилки / дисковые мельницы

        Ступковые мельницы

         

        Просеивание

        Вибрационные грохоты

        Мощные аналитические грохоты

         

        Деление / загрузка / очистка

        Делитель проб

        Дозирующие лотки

        Ванны для ультразвуковой очистки

      • Продукция для измерения частиц

         

        Лазерная дифракция

        Диапазон измерений 0,08 – 2.000 мкм

        Измерительный блок

        Мокрое диспергирование

        Сухое диспергирование

        Вертикальная шахта

        Диспергирование малых количеств в жидкой среде

        Программное обеспечение

         

        Диапазон измерений 0,01 – 2.000 мкм

        Измерительный блок

        Мокрое диспергирование

        Сухое диспергирование

        Вертикальная шахта

        Диспергирование малых количеств в жидкой среде

        Программное обеспечение

         

        Динамическое рассеяние света DLS:

        Диапазон измерений 1 нм – 6 мкм

      • Ссылки

         

        Другие домены

        www.fritsch-milling.com

        www.fritsch.de

        www.fritsch-france.fr

        www.fritsch.es

        www.fritsch-italy.it

        www.fritsch.com.sg

        www.fritsch.cn

        www.fritsch.jp

        www.fritsch.kr

         

        www.fritsch-sizing.ru

        www.fritsch-sizing.com

        www.fritsch-sizing.de

        www.fritsch-sizing.fr

        www.fritsch-sizing.es

        www.fritsch-sizing.it

        www.fritsch-sizing.com.sg

        www.fritsch-sizing.cn

        www.fritsch-sizing.jp

        www.fritsch-sizing.co.kr

      • Вход для зарегистрированных пользователей

        Введите свой ​​адрес электронной почты и пароль:

        Забыли пароль?

      • Please complete the form below for your account: